====== Downloads ======

===== Metrological (Calibration) Confirmation / Verification Procedures ===== 

{{ :metrology:to_33k1-4-141-1_30-aug-05_multimeters.pdf |T.O. 33k1-4-141-1, Calibration Procedure for Multimeters (30 August 2005) Size=765k}}

{{ :metrology:t.o._33k6-4-15-1-calibration_procedure_for_micrometers_micrometer_heads_and_depth_micrometers-general.pdf|T.O. 33k6-4-15-1, Calibration Procedure for Micrometers, Micrometer Heads, and Depth Micrometers-General (30 April 2008) Size=2M}}

{{ :metrology:t.o.33k6-4-552-1_calibration_procedure_for_calipers-general.pdf|T.O. 33k6-4-552-1, Calibration Procedure for Calipers-General (30 July 2013) Size=206k}}

{{ :metrology:t.o._33k6-4-1626-1_height_gages-vernier_dial_and_digital-general.pdf |T.O. 33k6-4-1626-1, Calibration Procedure for Height Gages - Vernier, Dial and Digital-General (30 March 2009) Size= 30k}}

{{ :metrology:t.o._33k6-4-2930-1-calibration_procedure_for_manually_operated_torque_wrenches-general.pdf|T.O. 33k6-4-2930-1, Calibration Procedure for Manually Operated Torque Wrenches 6% to 20% - General (30 September 2002 with Change 4, 30 May 2005) Size=99k}}

{{ :metrology:t.o._33k6-4-427-1_calibration_procedure_for_pressure-gauge.pdf |T.O. 33k6-4-427-1, Calibration Procedure for Pressure Gauge (30 May 2012) Size=101k}}

{{ :metrology:t.o._33k5-4-42-1-calibration_procedure_for_thermometers.pdf |T.O. 33k5-4-42-1, Calibration Procedure for Thermometers (30 January 2006) Size=60k}}

----

Federal Specifications, section 4, "Quality Assurance Provisions", addresses methodologies for calibration:

{{ :metrology:ggg-g-15c-gage_blocks_and_accessories.pdf |GGG-G-15C, Federal Specification: Gage Blocks and Accessories (Inch and Metric) (March 20 1975) Size=2.3M}}

{{ :metrology:ggg-g-17c-gages_general_purpose.pdf |GGG-G-17C, Federal Specification: General Purpose Gages (June 26 1987) Size=3.1M}}

{{ :metrology:ggg-c-105c-caliper_micrometer_inside_outside_tube_and_gage_depth_micrometer.pdf |GGG-C-105C, Federal Specification: Caliper; Micrometer (Inside, Outside, Tube) and Gage, Depth Micrometer (July 10 1987) Size=2.1M}}

{{ :metrology:ggg-p-463c-surface_plate_granite_.pdf |GGG-P-463C, Federal Specification: Surface Plate (Granite) (September 10, 1973) Size=1.7M}}

{{ :metrology:ggg-p-463c_amendment-1.pdf |GGG-P-463C, Federal Specification: Surface Plate (Granite) - Amendment 1 (June 15, 1977) Size=402k}}

{{ :metrology:ggg-r-791h-measuring_rules.pdf |GGG-R-791H, Federal Specification: Measuring Rules (19 July 1994) Size=993k}}

----

The [[https://www.usbr.gov/tsc/techreferences/mands/rockmanual/rockmanual.html#9300|"Technical Service Center"]] for the "U.S. Department of the Interior Bureau of Reclamation" also has several publically available calibration procedures. One of their most popular calibration procedures is:

[[https://www.usbr.gov/tsc/techreferences/mands/rockmanual/tan_earthmanualUSBR/USBR1007.pdf|USBR 1007-89, "Procedure for Calibrating Dial Indicators"]]

----

For calibrating most weighing scales, refer to [[https://www.nist.gov/pml/weights-and-measures/publications/nist-handbooks/other-nist-handbooks/other-nist-handbooks-0|NIST Handbook 44]], section 2.20, subsection N.1.1, "Test Procedures".

===== "SWOT & Strategic Risk Assessment Bubble Chart" template in Excel (8-12-2018) =====
[{{:swot_and_strategic_risk_analysis-template-excel-8-12-2018_screenshot.png?nolink&600|SWOT & Strategic Risk Assessment Bubble Chart (Excel)}}]

<WRAP clear></WRAP>
{{ :swot_and_strategic_risk_analysis-template-excel-8-12-2018.xlsx |SWOT & Strategic Risk Assessment Bubble Chart (Excel)}} \\
The "SWOT & Strategic Risk Assessment Bubble Chart" template (Excel)" is based on the guidance provided from ISO 31000:2018, "Risk management — Principles and guidelines". Use the SWOT to help identify up to 9 strategic risks. Then assign a point score (0-10) for the likelihood (probability) and "Consequences" (Impact) of each risk. These two scores ("Likelihood" and "Consequences") will automatically be added to produce a "Risk Level" (between 1 and 10). And the "Bubble" chart will automatically update; reflecting the "Risk Level" both in location and size of the bubbles. The template also includes a "Risk Treatment Plan" (as per ISO 31000:2009, section 6.4). This template includes instructions for its use.

===== "Process Risk Assessment Bubble Chart" template in Excel (8-12-2018) =====
[{{:process_risk_management-bubble_chart_template-excel-8-12-2018_screenshot.png?nolink&600 |Process Strategic Risk Assessment Bubble Chart (Excel)}}]

<WRAP clear></WRAP>
[{{ :process_risk_management-bubble_chart_template-excel-8-12-2018.xlsx?linkonly |Process Risk Assessment Bubble Chart (Excel)}} \\
The "Process Risk Assessment Bubble Chart" template (Excel)" is based on the guidance provided from ISO 31000:2018, "Risk management — Principles and guidelines". Identify up to 9 risks in a process. Then assign a point score (0-5) for the likelihood (probability) and "Consequences" (Impact) of each risk. These two scores ("Likelihood" and "Consequences") will automatically be added to produce a "Risk Level" (between 1 and 10). And the "Bubble" chart will automatically update; reflecting the "Risk Level" both in location and size of the bubbles. The template also includes a "Risk Treatment Plan" (as per ISO 31000:2018, section 6.4). This template includes instructions for its use.

===== "Calibration Recall" template Excel (5-5-2018) =====

{{:calibration_recall_screenshot.png?direct&600 |Calibration Recall template screenshot}}
<WRAP clear></WRAP>
{{ :calibration_recall_template-excel-5-5-2018.xls |"Calibration Recall" template Excel (5-5-2018)}} \\
This simple Excel-based "Calibration Recall" template is designed for small companies (with under 150 instruments under calibration control) to comply with ISO 9001:2015 & AS9100D. It uses Color-coded "Conditional Cell Formatting" for visual management. 

===== "DPMO-Sigma-Yield-Cpk Conversion Table Wallpaper" (1920x1080) =====

[{{:dpmo-sigma_conversion_wallpaper.png?direct&600 |"DPMO-Sigma-Yield-Cpk Conversion Table Wallpaper" (1920x1080)}}]
<WRAP clear></WRAP>
{{:dpmo-sigma_conversion_wallpaper.png?linkonly |"DPMO-Sigma-Yield-Cpk Conversion Table Wallpaper" (1920x1080)}} \\
This is a "DPMO-Sigma-Yield-Cpk Conversion Table" with a black background, suitable for use as computer desktop wallpaper. The PNG image provides a quick reference to convert Yields to DPMOs to Sigma levels (Short Term & Long Term) as well as Cpk. This chart covers a range of 3.50 to 6.00 Sigma Short Term (Z<sub>ST</sub>). And the row at 4.00 Sigma Short Term (Z<sub>ST</sub>) is highlighted in light green to indicate a minimum acceptable process capability of 1.33 Cpk.